Troubleshooting, Power module failure, Symptom – H3C Technologies H3C SecPath F5000-S Firewall User Manual

Page 61: Solution, Fan failure, Configuration terminal display problem

Advertising
background image

52

Troubleshooting

Power module failure

Symptom

The firewall cannot be powered on, and the power LED (PWR1/PWR2) on the front panel is off.

Solution

1.

Power off the firewall.

2.

Verify that the power supply is as required by the firewall.

3.

Verify that the power cords of the firewall are firmly connected.

4.

Verify that the power cords are not damaged.

5.

If the cause cannot be located in the steps above and the problem persists, contact your local sales
agent.

Fan failure

Symptom

After the firewall is booted, the following information appears on the configuration terminal:

%Jun 22 16:11:37:485 2013 H3C DEV/4/FAN FAILED:

Fan 1 failed.

The output indicates that the fan tray is not in position.

Solution

1.

Verify that the fan tray is in position.

2.

Verify that the fan tray is in firm contact with the backplane of the firewall chassis.

3.

If the cause cannot be located in the steps above and the problem persists, contact your local sales
agent.

Configuration terminal display problem

Symptom

The configuration terminal displays nothing or garbled text when the firewall is powered on.

Solution

1.

Verify the following items:

{

The power supply system is operating properly.

{

The console cable is properly connected.

2.

If no problem is found, examine the following reasons that might apply:

Advertising
This manual is related to the following products: