Before connecting an optical fiber, make sure the connector and cable type match the hot

swappable interface module.

The fiber Ethernet port of the firewall supports only the LC connector.

Fiber connectors are fitted with dust caps. Keep the dust caps properly when the fiber connectors

are in use. Install dust caps when the fiber connectors are not in use to avoid damage to their end
face. Replace the dust cap if it is loose or polluted.

Before connecting an optical fiber, use dust free paper and absolute alcohol to clean the end face
of the two fiber connectors. You can brush the end faces only in one direction.

Never bend or curve a fiber when connecting it.

If the fiber has to pass through a metallic board hole, when passing through a metallic board hole
or bending along the acute side of mechanical parts, the fiber must wear jackets or cushions.