2 remote feature to inverter compatibility, 0 setup – Magnum Energy ME-RC Remote User Manual

Page 16

Advertising
background image

9

©2013 Magnum Energy, Inc.

3.0 Setup

3.2

Remote Feature to Inverter Compatibility

The ME-RC has many settings and is designed to work with the standard

features in your Magnum inverter—and/or other Magnum devices (i.e., ME-

AGS-N or ME-BMK). The ME-RC communicates with your inverter to allow

the set up and enabling of these standard features. However, when the ME-

RC is released with new software, some of the features and functionality in

the remote may not be available in an inverter or networked accessory that

has an earlier software level. In this case, the setting is not recognized and

will not function. Use the steps below to help you determine which ME-RC

(Revision 2.8) menus/features are compatible with your inverter.
1. Go

to:

http://www.magnumenergy.com/Service/Compatibility.htm

to

determine your inverter’s compatibility level (L1, L2, L3, or L4).

2. Use Table 3-1 to determine which ME-RC features/settings you want to

use, and what inverter compatibility level is required (see the “Inverter

Model/Level Required” column in Table 3-1).

3. If your inverter compatibility level is the same or greater than the level

required, your inverter can support the setting/feature you want.

4. If your inverter does not have the required compatibility level for a fea-

ture/setting you want, contact Magnum Energy for a software upgrade.

Info: The ME-RC compatibility matrix below is also available online to

download/print as a single page document and to enter user settings.

http://www.magnumenergy.com/Service/Compatibility.htm

.

Table 3-1, ME-RC (Revision 2.8) Compatibility Matrix

Button

FEATURES/SETTINGS

Inverter

Model/

Level

Required

Default

Setting

Menu

Heading

Menu Item

Selections/

Adjustments Range

SHORE

Shore Max

5 - 60A

≥Level 1

[1]

30A

AGS

01 AGS

Control

AGS= OFF, Enable, Test, Enable

w/QT (Set Time)

≥Level 1

OFF**

02 AGS

Status

AGS: Read only display

≥Level 1

Read Only

03 Run

Time Hour

Run Time= 0.5 - 25.5 Hours

≥Level 1

2.0 Hrs

04 Start

Temp F

Start Temp= OFF, Ext Input, 65 - 95F

≥Level 1

OFF

05 Start

Volts

Start VDC= OFF, 10.0 - 12.2*

≥Level 1

11.0

06 Set

Time

Hour= 01:xxx-12:xxx

≥Level 1

12:00A

Minute= xx:00x-xx:59x

AM-PM= xx:xxA-xx:xxP

07 Quiet

Time

Quiet=

OFF,

9PM- (7AM/8AM/9AM),

(10PM/11PM) - 8AM

≥Level 1

OFF