B.1.5 hd sdi, B.1.5, Table b.6 – Ericsson Multi-Format Receiver RX1290 User Manual

Page 120

Advertising
background image

Technical Specification

Parameter Value

for

Y, R, G, B

Value for
Pb, Pr

Condition Notes

Inter-channel delay < 10 nS

< 10 nS

100% color bar

Interchannel
crosstalk

< -40 dB

< -40 dB

Multiburst

Blanking rise and
fall time

100 nS

± 50 nS

100 nS

± 50 nS

Flat field

20% to 80%

Active line width
inequality

<50 nS

<50 nS

Flat field

Sync edge to start
of active picture

2.586uS +80nS/-0nS

2.586uS +80nS/-0nS

50% to 50%

Sync amplitude
Pos and Neg

300mV

± 5%

300mV

± 5%

Tri-level Sync rise
and fall time

54 nS

± 20 nS

54 nS

± 20 nS

20% to 80%

Output impedance

75

Ω nominal

75

Ω nominal

Return loss

DC to 20 MHz > 20 dB

DC to 20 MHz > 20 dB

Table B.6 Sync Output Specification

Parameter Value

Condition

Notes

H and V Sync.
High Voltage

>2.5V 2.2k Ω

H and V Sync.
Low Voltage

<0.5V 2.2k Ω

B.1.5

HD SDI

HD SDI output supports:

• Embedded

Decoded

Audios

• Closed Captioning (EIA 708B)

• VITC

• VANC

EN/LZT 790 0003/2 R1A