4 100/1000baset dual ip input – rx1290/hwo/gige, 100/1000baset dual ip input – rx1290/hwo/gige -13, Table 3.9 – Ericsson Multi-Format Receiver RX1290 User Manual

Page 51: Setting up the dual ip interface -13

Advertising
background image

Operating the Equipment Locally

3.6.4

100/1000BaseT Dual IP Input – RX1290/HWO/GIGE

Steps through the set-up procedure of the Receiver using
Menu 2 Input, and the IP input.

Table 3.9 Setting Up the Dual IP Interface

Step Action

Result

1

Connect the Ethernet cables to
the IP input connectors.

2

Power up the unit and navigate
to Menu 2 Input.

Accesses the Input menu.

3

Navigate to NETWORK
INTERFACE 1

Accesses parameters of Port 1

4

Navigate to IP ADDRESS, then
press Edit.
Select the IP address, then
press Save.

Edits the IP Input address parameter.

5

Navigate to NET MASK
ADDRESS, then press Edit.
Select the Subnet mask, then
press Save.

Edits the IP Input subnet mask parameter.

6

Navigate to GATEWAY
ADDRESS, then press Edit.
Select the Gateway address,
then press Save.

Edits the IP Input Gateway address parameter.

7

Navigate to NETWORK
INTERFACE 2 and repeat steps
4, 5 and 6

Accesses and edits parameters of Port 2

8

Navigate to LISTENING
STREAM 1

Accesses parameters of listening multicast 1

9

Navigate to MCAST IP, then
press Edit.
Select the IP address, then
press Save.

Edits the Listening IP address parameter.

10

Navigate to UDP PORT, then
press Edit.
Select the UDP port number,
then press Save.

Edits the Listening UDP port number parameter.

11

Navigate to LISTENING
STREAM 2 and repeat steps 9
and 10

Accesses and edits parameters of listening
multicast 2

EN/LZT 790 0003/2 R1A

3-13