3 10/100baset input – rx1290/hwo/ip, 10/100baset input – rx1290/hwo/ip -12, Table 3.8 – Ericsson Multi-Format Receiver RX1290 User Manual

Page 50: Setting up the ip interface -12

Advertising
background image

Operating the Equipment Locally

3.6.3

10/100BaseT Input – RX1290/HWO/IP

Table 3.8 steps through the set-up procedure of the Telco Receiver using
Menu 2 Input, and the IP input.

Table 3.8 Setting Up the IP Interface

Step Action

Result

1

Connect the Ethernet cable to
the IP input connector.

2

Power up the unit and
navigate to Menu 2 Input.

Accesses the Input menu.

3

Navigate to UDP PORT (Menu
2.3.2), then press Edit.
Select the Receive UDP Port
number, then press Save.

Edits the UDP Port parameter.

4

Navigate to IP INPUT IP
ADDRESS (Menu 2.3.2.1),
then press Edit.
Select the IP address, then
press Save.

Edits the IP Input address parameter.

5

Navigate to IP INPUT
SUBNET MASK (Menu
2.3.2.2), then press Edit.
Select the Subnet mask, then
press Save.

Edits the IP Input subnet mask parameter.

6

Navigate to IP INPUT
GATEWAY ADDRESS (Menu
2.3.2.3), then press Edit.
Select the Gateway address,
then press Save.

Edits the IP Input Gateway address parameter.

7

Navigate to IP INPUT
MULTICAST IP ADD (Menu
2.3.2.4), then press Edit.
Select the Multicast IP
address, then press Save.

Edits the IP Input Multicast IP address parameter.

8

Return to Input Menu 2, it
should display the current
status. If status is NOT
LOCKED, verify that the cable
is properly connected and that
all values have been entered
correctly.