3 setting down conversion mode, 4 setting sd monitor aspect ratio, Setting down conversion mode -15 – Ericsson Multi-Format Receiver RX1290 User Manual

Page 53: Setting sd monitor aspect ratio -15, Table 3.12, Setting down conversion -15

Advertising
background image

Operating the Equipment Locally

Step Action

Result

3

Scroll to Menu 3.1.7 and edit
the video test pattern to be
displayed. Press Save.

Edits the video test pattern to be displayed.

4

Scroll to Menu 3.1.10 and edit
the parameter for framesync
enable (ENABLED or
DISABLED). Press Save.

Edits the parameter for framesync enable.

5

Scroll to Menu 3.1.10.1 and
edit the PAL framesync offset
range (-199999 to +199999
pixels) and the NTSC
framesync offset range (-
199999 to +199999 pixels).
Press Save.

Edits the PAL framesync offset range and the
NTSC framesync offset range.

6

Scroll to Menu 3.1.14 and
Menu 3.1.15 edit the
embedded audio group
(NONE, ONE, TWO, THREE
or FOUR). Press Save.

Edits the embedded audio data IDs and audio
channel.

3.7.3

Setting Down Conversion Mode

This menu allows the user to set the receiver to produce a down converted SD
version of the incoming HD video source.

Note: The RX1290 provides ‘grade 2’ down conversion video quality. The

suitability of grade 2 video for broadcast will depend on the intended
application.

Table 3.12 Setting Down Conversion

Step Action

Result

1

Scroll to Menu 3.1.8 and edit
the parameter for down
conversion enable
(ANAMORPHIC, CROPPED,
LETTERBOX or DISABLED).
Press Save.

Edits the parameter for down conversion enable
and the output format.

3.7.4

Setting SD Monitor Aspect Ratio

This menu allows the user to set the SD output aspect ratio.

Note: This function only applies to 4:2:0 video, and has no effect on the down

converted SD output

EN/LZT 790 0003/2 R1A

3-15

Advertising