5 configuring the unit for remote control overair, 1 overview, 2 oac lockout – Ericsson Multi-Format Receiver RX1290 User Manual

Page 70: Overview -4, Oac lockout -4, Table 4.2, Table 4.3, Activating director ncp remote control -4

Advertising
background image

Operating the Equipment Remotely

Table 4.2 Configuring the Serial Remote Port and Activating Remote Protocol

Step Action

Result

1.

Go to menu 7.1.

Displays ‘OPERATING MODE’.

2. Press

Edit.

Displays ‘FRONT PANEL’.

3.

Press the down pushbutton
and select ‘SERIAL REMOTE’.

The settings should be set to match the external
control host.

4. Press

Save.

The unit is ready for Remote Control.

Once the communication parameters are entered correctly, set the system into
remote mode for the external computer to gain control of the unit:

Step Action

Result

1.

Go to menu 7.1.2.

Displays ‘SERIAL REMOTE PROTOCOL’.

2. Press

Edit.

Toggle between RS-232 Alteia or RS-485 Alteia.

3.

Chose between RS-232 Alteia
or RS-485 Alteia.

The settings should be set to match the external
control host.

4. Press

Save.

The unit is ready for Remote Control.

4.1.5

Configuring the Unit for Remote Control Over-air

4.1.5.1

Overview

For the unit to be controlled via over-air control (OAC), the control mode of the Multi-
Format Receiver needs to be set to Director NCP.

Table 4.3 Activating Director NCP Remote Control

Step Action

Result

1.

Go to menu 7.1.

Displays ‘OPERATING MODE’.

2. Press

Edit.

Displays ‘FRONT PANEL’.

3.

Press the down pushbutton
and select ‘DIRECTOR NCP’.

The settings should be set to match the external
control host.

4. Press

Save.

The unit is ready for OAC.

4.1.5.2

OAC Lockout

Once the unit is in OAC control mode, it is possible for the remote control operator
to issue a local lockout command to the Receiver. This will effectively deny the local
user access to configuring the unit.

EN/LZT 790 0003/2 R1A

4-4