11 setting up system parameters (menu 7), Setting up system parameters (menu 7) -27, Table 3.41 – Ericsson Multi-Format Receiver RX1290 User Manual

Page 65: Setting up a system -27

Advertising
background image

Operating the Equipment Locally

Step Action

Result

6

Scroll to Menu 6.4 and edit the
AUDIO 2 menu (NO ALARM,
SET ALARM ONLY). Press Save.

Edits the Audio 2 alarms menu.

7

Scroll to Menu 6.5 and edit the
AUDIO 3 menu (NO ALARM,
SET ALARM ONLY). Press Save.

Edits the Audio 3 alarms menu.

8

Scroll to Menu 6.6 and edit the
AUDIO 4 menu (NO ALARM,
SET ALARM ONLY). Press Save.

Edits the Audio 4 alarms menu.

9

Scroll to Menu 6.7 and edit the
MER menu (NO ALARM, SET
ALARM ONLY). Press Save.

Edits the MER Error Rate (00.0 to 69.9) and
status menu.

10

Scroll to Menu 6.8 and edit the
BER menu (NO ALARM, SET
ALARM ONLY). Press Save.

Edits the BER Error Rate (00.0 to 69.9) and
status menu.

11

Scroll to Menu 6.9 and edit the
EBNO menu (NO ALARM, SET
ALARM ONLY). Press Save.

Edits the EBNO

12

Scroll to Menu 6.10 and edit the
TEMPERATURE menu (NO
ALARM, SET ALARM ONLY).
Press Save.

Edits the Temperature menu.

3.11

Setting Up System Parameters (Menu 7)

This menu gives access to the Set-up Menu to set-up and edit System Parameters
as well as the Multi-Format Receiver Details menu (see Table 3.42).

Table 3.41 Setting Up a System

Step Action

Result

1

Go to Menu 7.

Accesses the System menu.

2

Scroll to Menu 7.1 and edit the
Operating Mode (FRONT PANEL,
SERIAL REMOTE, NCP or NETWORK
(SNMP). Press Save.

Edits the Operating Mode menu.

3

Scroll to Menu 7.1.1 and edit the LCD
Contrast (LOW, MEDIUM or HIGH).
Press Save.

Edits the LCD Contrast.

4

Scroll to Menu 7.1.2 and edit the
SERIAL REMOTE PROTOCOL mode
(RS232 ALTEIA or RS485 ALTEIA).

Select the interface needed for serial
remote control.

5

Scroll to Menu 7.1.3 and edit the IP
Address. Press Save.

Edits the IP Address.

EN/LZT 790 0003/2 R1A

3-27

Advertising