B.5.3.2 high speed data over ethernet, B.5.4 snmp remote control connector, B.5.5 alarm connector – Ericsson Multi-Format Receiver RX1290 User Manual

Page 135: B.5.3.2, B.5.4, B.5.5, Table b.26, Table b.27, Table b.28

Advertising
background image

Technical Specification

B.5.3.2

High Speed Data over Ethernet

This connector is located at the back of the unit using the RJ-45 Ethernet port and is
enabled through the license key (RX1290/SWO/HSETHER).

Table B.26 High Speed Data Over Ethernet Connector

Item Specification

Safety status

SELV

Connector Type

RJ-45 (100BaseT)

Connector designation

10/100BaseT

Data rates (bit/s)

5 Mbps

Standards

ETSI EN 301 192 v.1.2.1 (1999-06), Section 4

De-encapsulation type

Data-Piping (Proprietary)

B.5.4

SNMP Remote Control Connector

Table B.27 SNMP Control Connector

Item Specification

Safety status

SELV

Connector type

RJ-45 (100BaseT)

Connector designation

10/100BaseT

Standard

Ericsson SNMP Control MIB

B.5.5

Alarm Connector

Table B.28 Relay Alarm Output Specification

Item

Specification

Safety status

SELV

Connector type

9-way D-type female

Connector designation:

ALARM

Contact Configuration

SPDT (Change-over)
All volt-free contacts, fully isolated.

Contact Rating

1 A at 24 V DC
1 A at 50 V AC

Maximum Switching Current

1 A

Maximum Switching Voltage

50 Vdc / 30 V AC

EN/LZT 790 0003/2 R1A

B-21