Default communication parameters, Default, Communication parameters – Kramer 4x4 Audio and Dante Mixer User Manual

Page 36

Advertising
background image

Kramer Electronics Ltd.

FC-404NETxl

– Technical Specifications

34

Default Communication Parameters

RS-232

Baud Rate:

115,200

Data Bits:

8

Stop Bits:

1

Parity:

None

Command Format:

ASCII

Example (set analog input 3 audio level to 10):

IN

.

ANALOG_AUDIO

.

3

.

AUDIO

.

1

,

10

<CR>

Ethernet

DHCP ON by default

IP Address:

192.168.1.39

Subnet mask:

255.255.255.0

Default gateway:

192.168.0.1

TCP Port #:

5000

UDP Port #:

50000

Default username:

Admin

Default password:

Admin

Device name:

FC-404Net-

{ID} where ID = the last 4 characters of the device’s serial number.

Dante

DHCP OFF by default

IP Address:

169.254.112.120

Subnet mask:

255.255.0.0

Default gateway:

169.254.0.0

Full Factory Reset

Webpages

Go to: Device Settings-> General -> RESET

Protocol 3000:

#factory

” command followed by “

#reset

” command.

Advertising