Opening the oscilloscope, Choosing a channel to display, View controls – MOTU Track16 - Desktop Studio FireWire/USB 2.0 Interface User Manual

Page 86: Horizontal controls (time axis)

Advertising
background image

C U E M I X F X

86

Level meters are displayed to the right of the graph.
One or two meters are shown, depending on the
current view mode (see “View controls”).

Opening the oscilloscope

Each Track16 has its own oscilloscope. To open an
oscilloscope, choose the

Oscilloscope

item from the

Devices menu under the desired interface.

Choosing a channel to display

The oscilloscope follows the currently focused
audio input or output. If you focus a mono channel
(e.g. Analog 3), its corresponding stereo pair will
be displayed (Analog 3–4).

View controls

The View controls (Figure 9-36) provide several
options for the oscilloscope display.

Figure 9-36: View controls

View menu

The View menu (Figure 9-36) lets you choose how
you wish to display the audio channel(s) being
displayed.

Display options

The

Axes

control (Figure 9-36) sets the opacity of

the grid displayed in the graph, from 100% (fully
visible) down to 0% (fully hidden). The

Show Ruler

option toggles the measurement items (see
“Measurement information” on page 89).

Pausing the display

The Pause button in the upper right corner of the
View section (Figure 9-36) allows you to freeze the
display at any time. To resume, click the button
again. The level meters will remain active while the
display is paused.

Horizontal controls (time axis)

The

Horizontal

controls (Figure 9-37) configure

the value range of the x-axis (time). Click and drag
the values up or down to set them, or double-click
to return to the default value.

There are two modes for the controls:

Zoom/Offset

and

Min/Max

. To change the mode, use the

Horizontal control menu (Figure 9-37).

Figure 9-37: Horizontal control menu

In

Zoom/Offset

mode,

Zoom

sets the display zoom

from 1/1000x to 10x, where the number represents
the number of pixels per sample. For example,
when the horizontal zoom value is 10x, 10 samples
are displayed in 100 pixels; when the horizontal
zoom value is 1/10x, 100 samples are displayed in
10 pixels.

Offset

moves the line marking time

equals zero left or right.

In

Min/Max

mode,

Min

and

Max

set the earliest

and most recent displayed time.

View menu settingWhat it displays

Left

Left channel only

Right

Right channel only

Split screen

Left channel on top; right channel on the bot-
tom

Shared

Left and right on top of each other; left is
green, right is red

Add

Left and right channels’ amplitudes are added
together

Subtract L-R

The right channel’s amplitude is subtracted
from the left channel’s amplitude

Pause button

View menu

Advertising