Opening the x-y plot, Choosing a channel pair to display, View controls – MOTU Track16 - Desktop Studio FireWire/USB 2.0 Interface User Manual

Page 92: Horizontal and vertical controls

Advertising
background image

C U E M I X F X

92

Opening the X-Y Plot

Each Track16 interface has its own X-Y Plot
window. Choose the

X-Y Plot

item from the

Devices menu under the desired interface.

Choosing a channel pair to display

The X-Y Plot follows the currently focused audio
input or output. If you focus a mono channel (e.g.
Analog 3), its corresponding stereo pair will be
displayed (Analog 3–4).

View controls

The View controls (Figure 9-43) provide several
options for the X-Y Plot display.

Figure 9-43: View controls

Pausing the display

The Pause button in the upper right corner of the
View section (Figure 9-43) allows you to freeze the
display at any time. To resume, click the button
again. The level meters will remain active while the
display is paused.

Line/Scatter

Choose either

Line

or

Scatter

from the menu in the

View section (Figure 9-43) to plot each point
(sample) as either a single pixel or as a continuous
line that connects each plot point to the next, as
shown below in Figure 9-44.

Figure 9-44: The same X-Y Plot displayed in Line versus Scatter mode.

Line mode is significantly more CPU intensive

than Scatter. You can reduce Line mode CPU
overhead on the X-Y Plot by reducing the Length
parameter (described below).

Color/Grayscale

In

Color

mode (Figure 9-43) the most recently

displayed audio data is shown in red, which fades
to yellow, green and then finally blue, before
disappearing. In Grayscale mode, data is first
shown in white and then fades to gray. To adjust the
scale of this color/brightness change, see “Decay”
on page 93.

Axes

The

Axes

control (Figure 9-43) sets the opacity of

the grid displayed in the graph, from 100% (fully
visible) down to 0% (fully hidden).

Horizontal and vertical controls

The

Horizontal

and

Vertical

controls (Figure 9-45)

configure the value range of the x-axis (left channel
amplitude), and y-axis (right channel amplitude),
respectively. Click and drag the values up or down
to set them, or double-click to return to the default
value.

There are two modes for the controls:

Zoom/Offset

and

Min/Max

. To change the mode, use the menu

shown in Figure 9-45.

Figure 9-45: Setting the Horizontal or Vertical control modes.

In

Zoom/Offset

mode,

Zoom

scales the axis.

Pos

moves the lines marking x = 0 left and right, or y =
0 up and down.

Pause button

Advertising