ROUBLESHOOTING

Control mode. Make sure that the control mode is set correctly.



Use Random mode (the default) with an application that controls the

autoloader.



Only use Sequential mode if you plan to operate without autoloader

software. In Sequential mode, the autoloader automatically processes

cartridges in sequential order without direction from an application. See

page 38

for more information about Sequential operation.

Hardware operation. You can verify that the autoloader hardware is

operating using the following methods:



Use the autoloader’s Diagnostics menu (under Demo Mode) to move

cartridges from random cells in and out of the tape drive. See

page 75

for

instructions.



Use the autoloader’s Command menu to import or export cartridges,

and to move specific cartridges into and out of the tape drive. See

page 64

for instructions.



Use LibTool to display the current inventory of cartridges, and to move

cartridges into and out of the tape drive. Refer to the program’s online

help for instructions on performing upgrades and diagnostics.

LibTool is available as a free download from

www.exabyte.com/downloads

.

If the autoloader reports an error during any of these tests, use LibTool to

obtain a diagnostic log from the autoloader immediately after the error is

reported (see

page 102

). Alternatively, if your autoloader is equipped with

the optional Ethernet port, you can use FTP to obtain a diagnostic log from

the autoloader (see

page 100

). Exabyte Technical Support can examine the

log to determine the nature of the reported error.

A

UTOLOADER

O

PERATION

If the autoloader has been successfully operating in the past, but is now

experiencing problems, check the following:

Control mode. If you are using application software to control the

autoloader, you must set the control mode to Random. Use Sequential mode

only if you are operating without autoloader software. See

page 38

.

Autoloader functions. You can use the selections in the Diagnostics menu to

check specific autoloader functions. See

page 77

for instructions.

!

! !

!

Important

After checking the items above, reset the autoloader as

described on

page 74

.

Advertising