Table c-1 – Exabyte MAGNUM 1X7 LTO User Manual

Page 150

Advertising
background image

134

P

RODUCT

M

ANUAL

1012581

A

PPENDIX

C—E

RROR

M

ESSAGES

Table C-1 Autoloader error messages

Error Message

Description

Corrective Action

Bootblock

An error occurred during a firmware

upload to the autoloader.

1.

Verify that you loaded the correct code.

Do not load firmware from one model

of autoloader or autoloader into

another.

2.

Reset the autoloader (see

page 74

) and

reload the firmware.

3.

If the error persists, contact Exabyte

Technical Support (see

page iii

) or your

service provider.

Cartridg.Invalid

An attempt was made to load an

incompatible cartridge into the tape

drive or a spent cleaning cartridge

and the cartridge was ejected.

ƒ

Remove the cartridge from the

autoloader and replace it with one that is

compatible with the tape drive.

ƒ

If you were attempting to import a

cleaning cartridge, insert a cartridge with

cleaning cycles remaining on it.

Command Failed

Check Ship Lock

The cartridge loader could not move

because it may be locked in place by

the shipping key.

Remove the shipping key (see

page 8

).

Command Failed

Drive is Full

A command was issued from the

operator panel to load a cartridge

into the tape drive when the drive

already contained a cartridge.

Wait until the current cartridge is unloaded

by the application, or use the operator

panel to unload it from the tape drive (see

page 69

).

Command Rejected

Carousel Full

A command was issued from the

operator panel to insert a cartridge

into the autoloader when all of the

cartridge cells were already full.

Export a cartridge from the autoloader to

make room for a new cartridge (see

page 66

).

Command Rejected

Empty Carousel

A command was issued from the

operator panel to either load a

cartridge into the tape drive or

remove a cartridge from the

autoloader when there were no

cartridges in the cartridge carousel.

Wait until the cartridge is ejected from the

tape drive, or use the operator panel to

import cartridges into the autoloader (see

page 64

).

Configuration

Locked by Host

The application is currently

controlling the autoloader (a SCSI

command is active) or the Remote

Management utility (see

Chapter 4

)

is controlling the autoloader.

Wait for the command from the application

to complete.

Device Not Ready

The autoloader is not ready to

perform the requested operation

because it is performing diagnostics

or its power-on self-test (POST).

Wait until the autoloader has finished, then

retry the operation.