Fault relay alarm, Ip configuration – Husky HME-423E User Manual

Page 20

Advertising
background image

Configuration Using a Web Browser

4-4

4-5.4 Fault Relay Alarm

The Fault Relay Alarm function provides the Power Failure and Port Link Down/Broken detection. With both
power input 1 and power input 2 installed and the check boxes of power 1/power 2 marked, the FAULT LED
indicator will then be possible to light up when any one of the power failures occurs. As for the Port Link
Down/Broken detection, the FAULT LED indicator will light up when the port failure occurs if the check box
beside the port is marked. Please refer to the segment of ‘Wiring the Fault Alarm Contact’ for the failure
detection.

Power Failure

The FAULT LED on the front panel of the HME-421E/423E will light up
when a power failure occurs if this box is checked.

Port Link Down/Broken

The FAULT LED on the front panel of the HME-421E/423E will light up
when a port link is down or broken if this box is checked.

After finishing necessary configurations, click on Apply to save the settings.

4-5.5 IP Configuration

This feature allows users to configure the IP settings and DHCP client function of the HME-421E/423E.

DHCP Client

Use this feature to enable or disable the DHCP Client function. When
DHCP Client is enabled, the HME-421E/423E will be assigned with an IP
address from the network DHCP server. The default IP address will be
replaced by the DHCP server-assigned IP address. After clicking on
Apply

button, a popup window will show up. It is to inform the

administrator that when the DHCP Client is enabled, the current IP will no
longer exist, and new one will be assigned by the DHCP server.

IP Address

Use this feature to assign an IP address to the HME-421E/423E. The
administrator will not need to assign an IP address to the
HME-421E/423E if the DHCP Client function is enabled, and this column
will show the IP address assigned by the DHCP server. The default IP is
192.168.16.1.

Subnet Mask

Use this feature to assign the subnet mask of the IP address. The
administrator will not need to assign the subnet mask if the DHCP Client
function is enabled.

Gateway

Use this feature to assign the network gateway for the industrial switch.
The default gateway is 192.168.16.254.

DNS1

Use this feature to assign the primary DNS IP address.

DNS2

Use this feature to assign the secondary DNS IP address.