B. Design and Installation Considerations

Heat & Glo direct vent gas appliances are designed to op-

erate with all combustion air siphoned from outside of the

building and all exhaust gases expelled to the outside of

the building. No additional outside air source is required.
Installation MUST comply with local, regional, state and

national codes and regulations. Consult insurance carrier,

local building inspector, fire officials or authorities having

jurisdiction over restrictions, installation inspection and

permits.
Before installing, determine the following:
• Where the appliance is to be installed.
• The vent system configuration to be used.
• Gas supply piping requirements.
• Electrical wiring requirements.
• Framing and finishing details.
• Whether optional accessories—devices such as a fan,

wall switch, or remote control—are desired.

D. Inspect Appliance and Components

• Carefully remove the appliance and components from

the packaging.

• The vent system components and decorative doors and

fronts may be shipped in separate packages.

• If packaged separately, the log set and appliance grate

must be installed.

• Report to your dealer any parts damaged in shipment,

particularly the condition of the glass.

Read all of the instructions before starting the instal-

lation. Follow these instructions carefully during the

installation to ensure maximum safety and benefit.

WARNING! Risk of Fire or Explosion! Damaged parts

could impair safe operation.

DO NOT install damaged, in-

complete or substitute components. Keep appliance dry.

C. Tools and Supplies Needed

Before beginning the installation be sure that the following

tools and building supplies are available.
Tape measure

Framing material

Pliers

Non-corrosive leak check solution

Hammer

Phillips screwdriver

Gloves

Framing square

Voltmeter

Electric drill and bits -

1/4 in. (6 mm)

Plumb line

Safety glasses

Level

Reciprocating saw

Manometer

Flat blade screwdriver

1/2 - 3/4 in. (13 - 19 mm) length, #6 or #8
Self-drilling screws
Caulking material (149 °C (300 °F) minimum continuous

exposure rating)
One 1/4 in. (6 mm) female connection (for optional fan).

Hearth & Home Technologies disclaims any responsibility for,

and the warranty will be voided by, the following actions:
• Installation and use of any damaged appliance or vent

system component.

• Modification of the appliance or vent system.
• Installation other than as instructed by Hearth & Home

Technologies.

• Improper positioning of the gas logs or the glass door.
• Installation and/or use of any component part not approved

by Hearth & Home Technologies.

Any such action may cause a fire hazard.

WARNING! Risk of Fire, Explosion or Electric Shock!

DO NOT use this appliance if any part has been under

water. Call a qualified service technician to inspect the

appliance and to replace any part of the control system

and/or gas control which has been under water.

Improper installation, adjustment, alteration, service or

maintenance can cause injury or property damage. For

assistance or additional information, consult a qualified

service technician, service agency or your dealer.