Rear Vent - Vertical Termination

One Elbow

Figure 7.16

Two Elbows

Figure 7.17

V

1

H

1

INSTALLED

HORIZONTALLY

H

1

H

2

V

1

USE DVP SERIES COMPONENTS ONLY

USE DVP SERIES COMPONENTS ONLY

V

1

Minimum

H

1

Maximum

1 ft.

305 mm

3 ft.

914 mm

2 ft.

610 mm

6 ft.

1.83 m

3 ft.

914 mm

8 ft.

2.44 m

4 ft.

1.22 m

11 ft.

3.35 m

5 ft.

1.52 m

12 ft.

3.66 m

V

1

+ H

1

= 36 ft. (10.97 m) Maximum

H

1

= 12 ft. (3.66 m) Maximum

V

1

Minimum

H

1

+ H

2

Maximum

2 ft.

610 mm

Back to Back 90º Elbows

1 ft.

310 mm

3 ft.

915 mm

2 ft.

610 mm

4 ft.

1.22 m

3 ft.

914 mm

8 ft.

2.44 m

4 ft.

1.22 m

10 ft.

3.05 m

V

1

+ H

1

= 32 ft. (9.75 m) Maximum

H

1

+ H

2

= 9 ft. (2.74 m) Maximum