C. Vent Components Diagrams (continued)

Figure 16.4 DVP vent components

DVP-TRAP2

DVP-TRAP2

Horizontal Termination Cap

15-1/8 in.

(384 mm)

12 in.

(305 mm)

8 in.

(203 mm)

Max

Effective

Length

Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm).

The heat shield is designed to be

used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm) the

existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a DVP-HSM-B

will be required.

Heat

Shield

1 in.

(25 mm)

14 in.

(356 mm)

3/8 in. (10 mm)

1 in. (25 mm)

7-1/4 in.

(184 mm)

7-3/4 to 10-3/8 in.

(197 to 264 mm)

DVP-FBHT

FireBrickTermination Cap

Term Cap

Minimum

Effective Length

Maximum

Effective Length

Trap2

5-3/8 in.

9-3/8 in.

137 mm

238 mm