Adjusting Thermostat

• Press the

MENU button to activate the menu.

• Using the

UP and DOWN arrows highlight the THERMO

icon and press

SELECT.

• Use the

UP and DOWN arrows to turn the THERMO ON

or

OFF, then press SELECT (the SET TEMP will start

blinking). Using the

UP and DOWN arrows select the

desired temperature and press

SELECT.

NOTICE: If the THERMO function is on, the SET TEMP

can be adjusted at any time by pressing the UP and DOWN

arrows.
NOTICE: As the ROOM TEMP (RT) approaches SET

TEMP (ST), the remote system will automatically adjust

the flame height. If the RT rises above ST, the fireplace

will shut down the main burner. After this, the fireplace will

turn back on after the RT drops below the ST.
NOTICE: The system will remember the previous TEM-

PERATURE setting when THERMOSTAT mode is cycled

ON or OFF.
NOTICE: If your installation includes an optional wired ON/

OFF wall switch, it should be in the OFF position when

using the RC300AU in thermostat mode.

Adjusting Timer

• Press the

MENU button to activate the menu.

• Using the

UP and DOWN arrows highlight the TIMER

icon and press

SELECT.

• Use the

UP and DOWN arrows to turn the TIMER ON

or

OFF, then press SELECT. Using the UP and DOWN

arrows select the desired set time and press

SELECT.

Timer operates in increments of 15, 30, 45, 60, 90, 120

and 180 minutes.

Setting the Child Lock

• Press and hold the

MENU and UP arrow buttons simul-

taneously for 4 seconds to enable or disable the child

lock feature.

NOTICE: No functions will be usable until child lock feature

is disabled.

Power Outage

• If fireplace battery backup system IS installed at time of

power outage, fireplace operation will not be interrupted.

• If fireplace battery backup system IS NOT installed at

time of power outage, fireplace will shut off. To resume

fireplace operation, install battery backup.

NOTICE: Battery polarity must be correct or module

damage will occur.

Manual Fireplace Shutoff

In the unlikely event that the remote wall switch malfunc-

tions and will not turn off the fireplace, call your dealer

for service assistance. In the meantime, you may choose

one of the following actions to turn off the fireplace:
CAUTION! Risk of burns! Fireplace surfaces are hot

when operating and during cool down. Use care and

wear gloves when opening the front and accessing com-

ponents inside the fireplace.
Check remote screen for battery level indicator, replace

the batteries if low battery is indicated (See Figure 12.13).
Turn off the control module:
• Open or remove the decorative front to access the control

module.

• Move switch to OFF (See Figure 12.11).
Disconnect power to the control module:
• Open or remove the decorative front to access power

cord and/or back-up batteries.

• Unplug the control module and/or remove back-up

batteries.

Shut off gas to the appliance:
• Open or remove the decorative front and locate the gas

shut-off valve to the left of the gas control.

• Rotate the shut off valve 90 degrees to turn off gas supply.
Turn off power to the fireplace (if back-up batteries

are not installed):
• Locate house circuit breaker for fireplace.
• Turn off the circuit breaker.