Top vent - vertical termination, Straight up vertical flue system – Heat & Glo Fireplace Heat & Glo 350TRSILP-AUF User Manual

Page 30

Advertising
background image

Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. R • 2/13

30

Top Vent - Vertical Termination

This model is approved to use DVP or SLP Series flue

pipe components. A

DVP-TVHW or SLP-TVHW vertical

Termination Cap must be used to terminate flue systems

in a vertical position.
Approved flue system components are labeled for identifi-

cation.

NO OTHER FLUE SYSTEMS OR COMPONENTS

MAY BE USED. Detailed installation instructions are in-

cluded with each flue termination kit and should be used

in conjunction with this manual.
WARNING! Risk of Fire! This gas appliance and flue

assembly must be flued directly to the outside and must

never be attached to a chimney serving a separate solid

fuel burning appliance. Each gas appliance must use a

separate flue system-common flue systems are prohibited.
WARNING! Risk of Fire! DO NOT apply combustible

materials beyond the minimum clearances. Comply with

all minimum clearances to combustibles as specified in

this manual. Overlapping material could ignite and will in-

terfere with proper operation of doors and louvers.
• Horizontal sections 3 in. (76 mm) from the top of the

pipe.

• Horizontal sections 2-1/2 in. (64 mm) at wall shield

firestops.

• Horizontal sections 1 in. (25 mm) from sides and bottom

of the pipe.

• Vertical sections 1 in. (25 mm) on all sides of pipe.
Failure to keep insulation or other material away from vent

pipe may cause over heating and fire.
For alternative installations, other than depicted, contact

your dealer for further information.

MODEL

FLUE TERMINATION APPROVALS

350TRSI-AUF

350TRSILP-AUF

SLP-TVHW, DVP-TVHW

Figure 7.8

Figure 7.7

V

MAX. RUN

36 ft.

(10.97 m)

Straight Up Vertical Flue System

Figure 7.7 shows straight up vertical flue system approved

for use on this model.

If the heater installation requires a vertical flue

exceeding 14-3/4 in. (4.5 m) above the unit

with no horizontal flue or elbows a vertical flue

restrictor must be installed (see Figure 7.7).

CAP

V

1

RESTRICTOR

PLATE

Advertising