IBM 6648 User Manual

Page 16

Advertising
background image

Diagnostic Error Code

FRU/Action

000-038-XXX

BIOS Extension failure

1.

Flash the system

2.

Adapter card

3.

System board

000-039-XXX

BIOS DMI data error

1.

Flash the system

2.

System board

000-195-XXX

BIOS Test aborted by user

1.

Information

2.

Re-start the test, if necessary

000-196-XXX

BIOS test halt, error threshold

exceeded

1.

Press F3 to review the log file

2.

Re-start the test to reset the log file

000-197-XXX

BIOS test warning

1.

Make sure the component that is called out is
connected and/or enabled

2.

Re-run test

3.

Component that is called out in warning statement

4.

Component under test

000-198-XXX

BIOS test aborted

1.

If a component is called out, make sure it is
connected and/or enabled

2.

Flash the system and re-test

3.

Go to the

″Undetermined problems″ section

000-199-XXX

BIOS test failed, cause unknown

1.

Go to the

Undetermined problemssection

2.

Flash the system and re-test

3.

Replace component under function test

000-250-XXX

BIOS APM failure

1.

Flash the system

2.

System board

000-270-XXX

BIOS ACPI failure

1.

Flash the system

2.

System board

001-000-XXX

System Test Passed

1.

No action

001-00X-XXX

System Error

1.

System board

001-01X-XXX

System Error

1.

System board

001-024-XXX

System Addressing test failure

1.

System board

001-025-XXX

System Checksum Value error

1.

Flash the system

2.

System board

001-026-XXX

System FLASH data error

1.

Flash the system

2.

System board

2

Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,

6649

Advertising