IBM 6648 User Manual

Page 24

Advertising
background image

Diagnostic Error Code

FRU/Action

015-015-XXX

USB port External Loopback

failure

1.

Remove USB device(s) and re-test

2.

System board

015-027-XXX

USB port Configuration/Setup

error

1.

Flash the system

2.

System board

015-032-XXX

USB port Device Controller failure 1. System board

015-034-XXX

USB port bufferallocation failure

1.

Reboot the system

2.

Flash the system

3.

Run memory test

4.

System board

015-035-XXX

USB port Reset condition detected 1. Remove USB device(s) and re-test

2.

System board

015-036-XXX

USB port Register error

1.

System board

015-040-XXX

USB port IRQ failure

1.

Run setup and check for conflicts

2.

Flash the system

3.

System board

015-195-XXX

USB port Test aborted by user

1.

Information

2.

Re-start the test, if necessary

015-196-XXX

USB port test halt, error threshold

exceeded

1.

Press F3 to review the log file

2.

Re-start the test to reset the log file

015-197-XXX

USB port test warning

1.

Make sure the component that is called out is
connected and/or enabled

2.

Re-run test

3.

Component that is called out in warning statement

4.

Component under test

015-198-XXX

USB port test aborted

1.

If a component is called out, make sure it is
connected and/or enabled

2.

Flash the system and re-test

3.

Go to the

″Undetermined problems″ section

015-199-XXX

USB port test failed, cause

unknown

1.

Go to the

Undetermined problemssection

2.

Flash the system and re-test

3.

Replace component under function test

018-000-XXX

PCI Card Test Passed

1.

No action

10

Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,

6649

Advertising