Pin main power supply connection – IBM 6648 User Manual

Page 45

Advertising
background image

20-pin main power supply connection

See “A40 and A40P system board layout” on page 67 for connector locations.

Attention

These voltages must be checked with the power supply cables connected
to the system board.

Pin

Signal

Function

1

3.3 V

+3.3 V dc

2

3.3 V

+3.3 V dc

3

COM

Ground

4

5 V

+5 V dc

5

COM

Ground

6

5 V

+5 V dc

7

COM

Ground

8

POK

Power Good

9

5VSB

Standby Voltage

10

12 V

+12 V dc

11

3.3 V

+3.3 V dc

12

-12 V

-12 V dc

13

COM

Ground

14

PS-ON

DC Remote Enable

15

COM

Ground

16

COM

Ground

17

COM

Ground

18

No voltage

Not used

19

5 V

+5 V dc

20

5 V

+5 V dc

If the voltages are not correct, and the power cord is good, replace the power
supply.

Chapter 2. Types 6568/6569/6648/6649

31

Advertising