IBM 6648 User Manual

Page 22

Advertising
background image

Diagnostic Error Code

FRU/Action

011-013-XXX
011-014-XXX

Serial port Control

Signal/Loopback test failure

1.

System board

011-015-XXX

Serial port External Loopback

failure

1.

Wrap plug

2.

System board

011-027-XXX

Serial port Configuration/Setup

error

1.

Run Setup, enable port

2.

Flash the system

3.

System board

011-03X-XXX
011-04X-XXX

Serial port failure

1.

System board

011-195-XXX

Serial port Test aborted by user

1.

Information

2.

Re-start the test, if necessary

011-196-XXX

Serial port test halt, error

threshold exceeded

1.

Press F3 to review the log file

2.

Re-start the test to reset the log file

011-197-XXX

Serial port test warning

1.

Make sure the component that is called out is
connected and/or enabled

2.

Re-run test

3.

Component that is called out in warning statement

4.

Component under test

011-198-XXX

Serial port test aborted

1.

If a component is called out, make sure it is
connected and/or enabled

2.

Flash the system and re-test

3.

Go to the

″Undetermined problems″ section

011-199-XXX

Serial port test failed, cause

unknown

1.

Go to the

Undetermined problemssection

2.

Flash the system and re-test

3.

Replace component under function test

011-2XX-XXX

Serial port signal failure

1.

External serial device

2.

System board

014-000-XXX

Parallel port Interface Test Passed

1.

No action

014-001-XXX

Parallel port Presence

1.

Remove external parallel device, if present

2.

Run setup, enable port

3.

System board

014-002-XXX
014-003-XXX

Parallel port Timeout/Parity error

1.

System board

8

Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,

6649

Advertising
This manual is related to the following products: