IBM 6648 User Manual

Page 33

Advertising
background image

Diagnostic Error Code

FRU/Action

175-199-XXX

Thermal Sensor(s) test failed,

cause unknown

1.

Go to the

Undetermined problemssection

2.

Flash the system and re-test

3.

Replace component under function test

175-250-XXX
175-251-XXX

Thermal Sensor(s) limit error

1.

Check fans

2.

Check Power supply

3.

Microprocessor

4.

System board

185-000-XXX

Asset Security Test Passed

1.

No action

185-XXX-XXX

Asset Security failure

1.

Flash system

2.

System board

185-278-XXX

Asset Security Chassis Intrusion

1.

Assure Asset Security Enabled

2.

C2 Cover Switch

3.

System board

201-000-XXX

System Memory Test Passed

1.

No action

201-XXX-XXX

System Memory error

1.

Replace the memory module called out by the
test

2.

System board

202-000-XXX

System Cache Test Passed

1.

No action

202-XXX-XXX

System Cache error

1.

Cache, if removable

2.

System board

3.

Microprocessor

206-000-XXX

Diskette Drive Test Passed

1.

No action

206-XXX-XXX

Diskette Drive error

1.

Diskette Drive Cable

2.

Check power supply voltages

3.

Diskette drive

4.

System board

215-000-XXX

CD-ROM Drive Test Passed

1.

No action

215-XXX-XXX

CD-ROM Drive error

1.

CD-ROM Drive Cable

2.

Check power supply voltages

3.

CD-ROM drive

4.

System board

217-000-XXX

Hard Disk Drive Test Passed

1.

No action

Chapter 1. IBM PC Enhanced Diagnostics error codes

19

Advertising