IBM 6648 User Manual

Page 168

Advertising
background image

POST Error Code

FRU/Action

151

Real-time clock failure

1.

System Board

161

Bad CMOS battery

1.

Run Setup

2.

CMOS Backup Battery (see “Safety
information” on page 185)

3.

System Board

162

Configuration mismatch

1.

Run Setup and verify Configuration

2.

Had a device been added, removed, changed
location? If not, suspect that device.

3.

Power-on external devices first, then power-on
computer

4.

CMOS Backup Battery (see “Safety
information” on page 185)
System Board

5.

System Board

162

And unable to run diagnostics

1.

Diskette Drive

2.

System Board

3.

Diskette Drive Cable

163

Clock not updating or invalid time set

1.

Time and Date Set?

2.

CMOS Backup Battery (see “Safety
information” on page 185)

3.

System Board

164

POST detected a base memory or extended

memory size mismatch error or RIMM socket 3 is
populated with a RIMM memory module

1.

Run Setup. Check System Summary menu for
memory size change. (See“Setup Utility
program” on page 122.)

2.

Run the Extended Memory Diagnostic tests

166

Boot Block Check Sum Error

1.

Run Flash Recovery using Boot Block. See
“Flash recovery boot block jumper” on page
131.

2.

System Board

167

Microprocessor installed that is not supported

by the current POST/BIOS

1.

Run Setup. Check Stepping level for the
BIOS level needed, then perform the flash
update.

2.

Processor

168

Alert on LAN error

1.

Run Setup. Check to see that Ethernet and
Alert on LAN are enabled.

2.

System Board

17X, 18X

1.

C2 Security

154

Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,

6649

Advertising
This manual is related to the following products: