Diagnostic Error Code

FRU/Action

086-198-XXX

Mouse Port interface test aborted

1.

If a component is called out, make sure it is
connected and/or enabled

2.

Flash the system and re-test

3.

Go to the

″Undetermined problems″ section

086-199-XXX

Mouse Port interface test failed,

cause unknown

1.

Go to the

Undetermined problemssection

2.

Flash the system and re-test

3.

Replace component under function test

089-000-XXX

Microprocessor Test Passed

1.

No action

089-XXX-XXX

Microprocessor failure

1.

Microprocessor(s)

2.

System board

089-195-XXX

Microprocessor Test aborted by

user

1.

Information

2.

Re-start the test, if necessary

089-196-XXX

Microprocessor test halt, error

threshold exceeded

1.

Press F3 to review the log file

2.

Re-start the test to reset the log file

089-197-XXX

Microprocessor test warning

1.

Make sure the component that is called out is
connected and/or enabled

2.

Re-run test

3.

Component that is called out in warning statement

4.

Component under test

089-198-XXX

Microprocessor test aborted

1.

Flash the system and re-test

2.

Go to the

″Undetermined problems″ section

089-199-XXX

Microprocessor test failed, cause

unknown

1.

If a component is called out, make sure it is
connected and/or enabled

2.

Go to the

″Undetermined problems″ section

3.

Flash the system and re-test

4.

Replace component under function test

170-000-XXX

Voltage Sensor(s) Test Passed

1.

No action

170-0XX-XXX

Voltage Sensor(s) failure

1.

Flash system

2.

System board

170-195-XXX

Voltage Sensor(s) Test aborted by

user

1.

Information

2.

Re-start the test, if necessary

170-196-XXX

Voltage Sensor(s) test halt, error

threshold exceeded

1.

Press F3 to review the log file

2.

Re-start the test to reset the log file

Chapter 1. IBM PC Enhanced Diagnostics error codes