IBM 6648 User Manual

Page 25

Advertising
background image

Diagnostic Error Code

FRU/Action

018-0XX-XXX

PCI Card Failure

1.

Riser card, if installed

2.

System board

018-195-XXX

PCI Card Test aborted by user

1.

PCI card

2.

Information

3.

Re-start the test, if necessary

018-196-XXX

PCI Card test halt, error threshold

exceeded

1.

Press F3 to review the log file

2.

Re-start the test to reset the log file

018-197-XXX

PCI Card test warning

1.

Make sure the component that is called out is
connected and/or enabled

2.

Re-run test

3.

Component that is called out in warning statement

4.

Component under test

018-198-XXX

PCI Card test aborted

1.

Make sure the component that is called out is
connected and/or enabled

2.

Flash the system and re-test

3.

Go to the

″Undetermined problems″ section

018-199-XXX

PCI Card test failed, cause

unknown

1.

Go to the

Undetermined problemssection

2.

Flash the system and re-test

3.

Replace component under function test

018-250-XXX

PCI Card Services error

1.

PCI card

2.

Riser card, if installed

3.

System board

020-000-XXX

PCI Interface Test Passed

1.

No action

020-0XX-XXX

PCI Interface error

1.

PCI card

2.

Riser card, if installed

3.

System board

020-195-XXX

PCI Test aborted by user

1.

Information

2.

Re-start the test, if necessary

020-196-XXX

PCI test halt, error threshold

exceeded

1.

Press F3 to review the log file

2.

Re-start the test to reset the log file

Chapter 1. IBM PC Enhanced Diagnostics error codes

11

Advertising