Diagnostic Error Code

FRU/Action

170-197-XXX

Voltage Sensor(s) test warning

1.

Make sure the component that is called out is
connected and/or enabled

2.

Re-run test

3.

Component that is called out in warning statement

4.

Component under test

170-198-XXX

Voltage Sensor(s) test aborted

1.

If a component is called out, make sure it is
connected and/or enabled

2.

Flash the system and re-test

3.

Go to the

″Undetermined problems″ section

170-199-XXX

Voltage Sensor(s) test failed, cause

unknown

1.

Go to the

Undetermined problemssection

2.

Flash the system and re-test

3.

Replace component under function test

170-250-XXX
170-251-XXX

Voltage Sensor(s) Voltage limit

error

1.

Power supply

2.

System board

170-254-XXX

Voltage Sensor(s) Voltage

Regulator Module error

1.

Voltage Regulator Module (VRM)

2.

Microprocessor

3.

System board

175-000-XXX

Thermal Sensor(s) Test Passed

1.

No action

175-0XX-XXX

Thermal Sensor(s) failure

1.

Flash system

2.

System board

175-195-XXX

Thermal Sensor(s) Test aborted by

user

1.

Information

2.

Re-start the test, if necessary

175-196-XXX

Thermal Sensor(s) test halt, error

threshold exceeded

1.

Press F3 to review the log file

2.

Re-start the test to reset the log file

175-197-XXX

Thermal Sensor(s) test warning

1.

Make sure the component that is called out is
connected and/or enabled

2.

Re-run test

3.

Component that is called out in warning statement

4.

Component under test

175-198-XXX

Thermal Sensor(s) test aborted

1.

If a component is called out, make sure it is
connected and/or enabled

2.

Flash the system and re-test

3.

Go to

″Undetermined problems″ section

18