Power-up sequence – Intermec 6710 User Manual
Page 199

SECTION 6
"
Indicator Lights
6710 Access Point User’s Guide 6-7
Power-Up Sequence
When you power on the access point, it performs a power-up
sequence that does the following:
"
Tests the indicator lights.
"
Tests the functional circuits.
"
Determines the operational status.
"
Determines the boot sequence.
You can monitor the power-up sequence through the
indicator lights. During power-up the lights operate in this
order:
1. LINK indicator light turns ON and stays ON.
2. STATUS, MODE, R-LINK, W-LINK, NIC1, and NIC2
lights blink three times to indicate they are
operational.
3. After the previous lights stop blinking, W-LINK light
blinks three more times.
4. About eight seconds after W-LINK stops blinking,
R-WINK, W-LINK, NIC1 and NIC2 lights either turn
ON or stay OFF to indicate the DIAG port’s baud rate
(see page 6-6).
5. MODE light blinks constantly to indicate it is in
network mode, the normal operating condition.
After the access point completes its boot sequence, it enters
its normal operating mode. During normal operation the
STATUS indicator light is OFF.