Pfs? - read pass/fail status, Rcc? - read cursor column – SIGMA LBA-708 User Manual

Page 256

Advertising
background image

Operator’s Manual

LBA-PC

256

0 = reference frame

NOTE: The detector origin is always the upper left corner so that y values increase going down and decrease going
up.

Returns:

PNW <configuration>

2

Key Type Value

Description

UpperLeft

I,I

X,Y - minimum allowable capture location

LowerRight

I,I

X,Y - maximum allowable capture location.

Note that the capture location plus the
capture size times the capture resolution

must be less than these values.

A.5.4.13 PFS? - read pass/fail status

:PFS?

Returns:

PFS <configuration>

Note: Only results that are tested are returned.

Key Type Value

Description

Label

S

Label string as displayed in the Results
window.

Status

B

0 = fail,
1 = pass


Example return:

:PFS Total=1;Peak=0;Centroid X=0;Centroid Y=1;;

Total, Peak, Centroid X, and Centroid Y are being tested. Total passed, Peak failed, Centroid X

failed, Centroid Y passed.