Key Type Value

Description

default = false

Results

B

true = synchronize remote results

download
Do not capture another frame until the

controller sends a :RDR? command and
reads the response data.
false = normal operation
default = false

A.5.4.23 WLD? - read current frame boundaries

This command returns the boundaries of the current frame as viewed in the beam window (i.e.,

this is the range of values that will be displayed in the status bar if you move the cursors in the

beam window from the upper left corner to the lower right corner). The commands :APT, :CHR,
:CUR require “world coordinates”. World coordinates are dependent on the frame size, capture

resolution, origin location, and pixel scale. This command returns the upper left and lower right

corners of world coordinates of the current frame.


Note: If the origin is set to upper left window or upper left detector then y values increase going down and decrease
going up.

:WLD?

Returns:

WLD <configuration>

2

Key Type Value

Description

UpperLeft

F,F

X,Y - upper left corner as viewed in beam

window

LowerRight

F,F

X,Y - lower right corner as viewed in beam
window

A.5.4.24 ZOM - zoom in/out

This command is identical to “:CAP ZoomIndex=z” and is provided for convenience. Allowable

range is defined by “:CAP?” and “NumZooms=n”.

:ZOM <configuration>

2

Key Type Value

Description

Zoom

L

new zoom [+|-]z
-z = zoom out