4 checking tcp connection properties – Siemens Simantic Net NCM for Industrial Ethernet S7 User Manual

Page 127

Advertising
background image

Configuring Communication Connections

127

SIMATIC NET NCM S7 for Industrial Ethernet
C79000-G8976-C129–06

4.6.4

Checking TCP Connection Properties

Overview Tab

The overview shows all the previously configured TCP connections and their
parameters (cannot be modified here).

For an example of this display, refer to Section 4.3.4 (the ISO transport
connection).

Parameter

Description

ID

This is the connection ID of the TCP connection (STEP 7 connection
configuration; DWORD).

Name (loc. endpoint)

Entered connection name. It identifies the TCP connection (8
character double width).

CPU / Applications

If you display all the ISO transport connections being operated in this
station in the multiprocessor mode (with PC stations: multiple
applications), the CPU/application that is the endpoint of the
particular connection is specified here.

R/S or via CP

With S7-CPs: Rack/slot of the local CP via which the connection is
established.

With PC stations: Display of the CP over which the connection is
maintained.

Partner address

Specifies the remote IP address of the connection.

Local port

Local port (8 characters default length)

Remote port

Remote port (8 characters default width)

Mode

Displays the mode configured in the ”Options” tab.

Status

Indicates the current configuration of the connection.
“Connections without assignment” are indicated by “No local CP/No
remote CP
” in the status column and a “!” character at the end of
the“Local ID” (for example: 0002 A000!).
Connections you are currently editing are also indicated by “!” at the
end of the local ID.

You can set the column widths in the “Overview” tab individually.

Connection Overview with Multiple CPUs in an S7 Station

If you operate more than one CPU in your S7 station, you can click the button to
extend the overview to the connections on all CPUs.