Configuring Communication Connections

94

SIMATIC NET NCM S7 for Industrial Ethernet

C79000-G8976-C129–06

In both projects, the same connection name must be configured in the
properties of the connection. The connection name is used as a textual
reference when the projects are merged. Based on the connection name it is
possible to assign the connection partner and synchronize the connection
properties.

Before the projects are merged, such connections are ”unspecified
connections” in terms of addressing; in other words, the partner addresses
remain empty.

Unspecified Connections

Connections to an as yet unknown device (for example a diagnostic unit) are
configured as “unspecified” connections. They can be specified later in the
Properties dialog.

You can create an unspecified connection simply by selecting station “unspecified”
for the connection partner when you create the connection. The unspecified
connection can be used in two ways (explained below based on the example of an
ISO-on-TCP connection (ISO transport and TCP connections are analogous):

S

Declare readiness for communication – passive connection establishment

The connection establishment is then set to passive (see settings in the
General tab).

The address setting for the ISO-on-TCP connection is then as follows:
The remote IP address is 0.0.0.0 and the remote TSAP is empty; in other
words, they are not relevant for the CP. When the connection is established,
any partner is accepted (partner = connection name that addresses the CP with
the correct IP address and TSAP).

It is also possible to use a partial specification; in other words, communication
is permitted with any partner that matches the specified TSAP.

S

Connection to a specific station in any project

The address setting for the ISO-on-TCP connection is then as follows:
You can specify the remote IP address and the port of any destination station.
The destination station can be in the current STEP 7 project or in another
project.

Use this method if you have not created a substitute object for the partner
station, for example SIMATIC S5, in the current project.

The following table lists the possible options.

Table 4-2

Meaning for Connection

Establishment

IP Address /

MAC Address

TSAP / Port

Possible Connection

Establishment

by any partner

empty

empty

passive

by any partner via specific TSAP

empty

specified

passive

to or by a specific partner

specified

specified

active / passive