5 numeric data / resource requirements of the fcs – Siemens Simantic Net NCM for Industrial Ethernet S7 User Manual

Page 173

Advertising
background image

Programming FCs (Functions) and FBs for S7 Ethernet CPs

173

SIMATIC NET NCM S7 for Industrial Ethernet
C79000-G8976-C129–06

5.5

Numeric Data / Resource Requirements of the FCs

Notice

Please note the version information of the blocks. Blocks with other versions have
different resource requirements.

Table 5-6

Information for FCs with an S7-400

NAME

Version

FC no.

Load

memory

bytes

Work

memory

bytes

MC7

Bytes

Local data

Bytes

AG_SEND

1.1

5

732

576

540

20

AG_RECV

1.1

6

656

522

486

20

AG_LOCK

1.0

7

272

200

164

6

AG_UNLOCK

1.0

8

256

186

150

6

AG_LSEND

3.0

50

1044

846

810

52

AG_LRECV

3.0

60

1190

992

956

58

Table 5-7

Information for FCs with an S7-300

NAME

Version

FC no.

Load

memory

bytes

Work

memory

bytes

MC7

Bytes

Local data

Bytes

AG_SEND

4.1

5

1916

1610

1574

50

AG_RECV

4.5

6

1408

1174

1138

40

AG_LOCK

4.0

7

748

636

600

34

AG_UNLOCK

4.0

8

712

604

568

32