Turn off the projector, and unplug the AC power cord

from the AC outlet.
First, clean up the dust on the projector and around

the air vents.

1

2

Press ▼ downwards on the filter cover to release the

latch and open the filter cover.

3

Put the new one back into the position and close

the filter cover. Make sure that the filter cartridge is

properly and fully inserted.

5

CAUTION

Make sure the filter cartridge is inserted in the

projector. If the filter cartridge is not inserted, the

projector cannot be turned on.

Do not put anything into the air vents. Doing so

may result in malfunction of the projector.

4

Reset the filter counter and the scroll counter (p.68).

6

Filter cover

Pull out the filter cartridge. When taking out the filter

cartridge, put your finger on the filter cartridge’s tab

and then pull.

Latch

Filter

cartridge

Tab

RECOMMENDATION

We recommend avoiding dusty/smoky environments

when operating the projector . Usage in these

environments may cause a poor image quality .

When using the projector under dusty or smoky

conditions, dust may accumulate on a lens, liquid crystal

panels, or optical elements inside the projector. Such

condition may degrade the quality of the projected image.

When the symptoms above are noticed, contact your

authorized dealer or service center for proper cleaning.

ORDER REPLACEMENT FILTER CARTRIDGE
Replacement filter cartridge can be ordered through

your dealer. When ordering, give the following

information to the dealer.

Model No . of your projector

PLC-ZM5000, PLC-ZM5000L

Replacement Filter Cartridge Type No .

POA-FIL-080 (Service Parts No. 610 346 9034)

Connect the AC power cord to the projector and turn

on the projector.

7

Maintenance and Care