Appendix, Status read command – Sanyo PJLINK PLC-ZM5000L User Manual

Page 91

Advertising
background image

Appendix

The command is sent from PC to the projector with the

format below;

'CR' [Command] 'CR'

Command: one character (refer to the command

table below.

The projector decodes the command and returns the

'Character string' with the format below;

Format

The tables on page 90 and 91 show the typical command lists for controlling the projector. Please consult

your local dealer for further information of other commands.

Command

Function

Projector

Return

Projector status

CR0

Status Read

00

Power On

80

Stand-by mode

40

Countdown

20

Cooling down

10

Power Malfunction

28

Cooling down at the temperature anomaly

24

Cooling down at Power Management mode

04

Power Management mode after Cooling down

21

Cooling down after the projector is turned off when the

lamps are out.

81

Stand-by mode after Cooling down when the lamps are out.

88

Stand-by mode after Cooling down at the temperature

anomaly.

2C

Cooling down when the projector is turned off by the shutter

management function.

8C

Stand-by mode after cooling down by the shutter

management function.

CR6

Temperature Read

%1 %2

%3

%1 = Temperature at Sensor 1 (˚C)
%2 = Temperature at Sensor 2 (˚C)
%3 = Temperature at Sensor 3 (˚C)
(ex.) %1 = 12.3˚C, %2 = 23.4˚C, %3 = 34.5˚C
--> The projector displays “12.3 23.4 34.5”
( For each sensor, two digit and the tenth place numbers

are displayed with a space between each temperature.)

?

Communication failure

Status Read Command

91

Advertising
This manual is related to the following products: