13-22 Key Operator Mode

Key Operator Mode

ECM (Electronic Copy Monitor) Function Setting [4] (continued)

E.C.M. Function Setting [3]

Use this function to turn ECM On or Off; or to select whether the copier will stop at the
time the count limit is reached, or after the current copy job is completed.

ECM Setting Menu Screen

ECM Function Setting Screen

1 Press [

HELP

] to display the Help Screen, then touch

Key Operator Mode

.

Enter a 4-digit key operator password, then touch

OK

to display the Key Operator

Mode Screen. (See note 1.)

2 Touch

[4] E.C.M. function setting

. The ECM Master Key Code Screen displays, if a

code is required.

3 Enter your 8-digit ECM master key code, then touch

OK

to display the ECM Setting

Menu Screen. (See note 2.)

4 Touch

[3] E.C.M. function setting

. The ECM Function Setting Screen will be displayed.

5 Touch

ECM On

to activate ECM or touch

ECM Off

to de-activate ECM.

The selected key will be highlighted.

6 Touch

Immediately

to stop the machine when the copy limit is reached.

In this case, the paper in process will be completed, and “Enter ECM password” will
display after the copier stops.
Touch

After job

to stop the machine after the current job is completed, when copy

limit is reached.
Touch

Warning

only to display a warning message when copy limit is reached.

The selected key will be highlighted.

7 Touch

OK

to complete the setting and return to the ECM Setting Menu Screen.

8 If other ECM setting changes are required, touch desired key, from [1]~[3].
9 Touch

PREVIOUS SCREEN

to restore the Key Operator Mode Screen. If other key

operator settings are required, select the desired menu item, from [1] to [18].

10 If no further changes are required, touch

PREVIOUS SCREEN

to restore the Basic

Screen to perform copying operations.

NOTES:

1 If an invalid Key operator password is entered, continue by entering the valid 4-digit password.
2 If an invalid ECM master key code is entered, continue by entering the valid 8-digit code.

Advertising