Malfunctions/warnings, 1. list of malfunctions, T-10 – Konica Minolta PagePro 1390 MF User Manual

Page 120

Advertising
background image

T-10

3.

MALFUNCTIONS/WARNINGS

• The CPU performs a self-diagnosis on the condition of the unit, and if a malfunction is

detected, the warning appears alternately with the error code in the display.

<Procedure for cancelling a malfunction display>

• Cancel the malfunction display by turning the machine off and then on again.

3-1.

List of Malfunctions

Malfunc-

tion Code

Malfunction Name

Description

008

Polygon mirror

motor error

• The LOCK signal is not detected within a predeter-

mined period of time that begins 1 second after the
Polygon Motor has been energized.

• No new LOCK signal is detected for a 1 second period

that begins 1.5 seconds after the first LOCK signal
was detected.

• The LOCK signal is not detected for a continuous 0.5

second period in a state in which the Polygon Motor
runs stably.

• The LOCK signal remains ON for a continuous 5 sec-

ond period or more when the Polygon Motor remains
deenergized.

010

Fuser fan motor

error

• The LOCK signal remains HIGH or LOW continuously

for a predetermined period of time while the Cooling
Fan Motor remains energized.

020

H. V. abnormal

• The Drum Charge Monitor Voltage (HVC_MON) signal

falls outside a predetermined range at any time after
the lapse of a predetermined period of time after the
Power Switch has been turned ON.

• The Image Transfer Voltage Monitor signal

(T_MON_V) and Image Transfer Current Monitor sig-
nal (T_MON_I) fall outside a corresponding predeter-
mined range.

040

Laser error

• The laser output exceeds the upper limit value.
• The laser output remains lower than the lower limit

value.

4558F4C504DA

Advertising