6) 100: fuser temperature low, 7) 200: fuser overheat, T-16 – Konica Minolta PagePro 1390 MF User Manual

Page 126

Advertising
background image

T-16

(6)

100: Fuser temperature low

<Detection Timing>

<Troubleshooting Procedure>

(7)

200: Fuser overheat

<Detection Timing>

<Troubleshooting Procedure>

Description

• The temperature detected by the Thermistor remains lower than the set temperature

continuously for a predetermined period of time while the fusing temperature control is
being provided. (The set temperatures are as follows: 140 °C during a print mode at 600
dpi; 70 °C during the standby mode.)

Relevant Electrical Parts

Fusing Unit
Thermistor (TH1)

Mechanical Control Board (PWB-A)
Thermostat (TS1)
Power Unit (PU1)

Step

Action

Ref. Page

WIRING DIAGRAM

Control Signal

Location

(Electrical Parts)

1

Replace the Thermistor (TH1).

☞ D-28

2

Replace the Fusing Unit.

E-8

3

Replace PWB-A.

☞ D-11

4

Replace the Power Unit (PU1).

☞ D-14

Description

• The temperature detected by the Thermistor remains higher than 235 °C for a predeter-

mined period of time while the fusing temperature control is being provided.

Relevant Electrical Parts

Fusing Unit
Thermistor (TH1)

Mechanical Control Board (PWB-A)
Thermostat (TS1)
Power Unit (PU1)

Step

Action

Ref. Page

WIRING DIAGRAM

Control Signal

Location

(Electrical Parts)

1

Replace the Thermistor (TH1).

☞ D-28

2

Replace the Fusing Unit.

E-8

3

Replace PWB-A.

☞ D-11

4

Replace the Power Unit (PU1).

☞ D-14

Advertising