Konica Minolta PagePro 1390 MF User Manual

Page 41

Advertising
background image

E-9

<Installation Procedure>

NOTE
• When replacing an individual part of the Fusing Unit due to a defective part or to correct

an image problem, see “Disassembling the Fusing Unit” in DIS/REASSEMBLY, ADJUST-
MENT”.

☞ D-28

1. Connect connector A.

2. Mount the Fusing Unit in the printer and secure it

in position by tightening the two screws.

3. Connect connectors B and C.

NOTE
• When installing the Fusing Unit, route the harness

as shown in the illustration, making sure that no
part of the harness is wedged between the Fusing
Unit and printer.

4136E017AC

A

B

C

Advertising