<Installation Procedure>

NOTE
When replacing an individual part of the Fusing Unit due to a defective part or to correct

an image problem, see “Disassembling the Fusing Unit” in DIS/REASSEMBLY, ADJUST-
MENT”.

D-28

1. Connect connector A.

2. Mount the Fusing Unit in the printer and secure it

in position by tightening the two screws.

3. Connect connectors B and C.

NOTE
When installing the Fusing Unit, route the harness

as shown in the illustration, making sure that no
part of the harness is wedged between the Fusing
Unit and printer.

4136E017AC

A

B

C