Image reading system: Foggy background or rough image

<Typical Faulty Image>

<Troubleshooting Procedure>

Step

Check

Result

Action

1

Is the machine in direct sunlight or sub-
ject to any other extraneous light?

YES

Protect the machine from direct
light.

2

Is the document damaged or dirty?

YES

Replace the document.

3

Is the Original Pad dirty?

YES

Clean it.

4

Does the Original Cover lie flat?

NO

If the Document Cover is
deformed or the hinges are dam-
aged, replace the Document
Cover.

5

Is the surface of the Original Glass dirty?

YES

Clean it.

6

Is the Shading Sheet or back surface of
the Original Glass dirty?

YES

Clean them.

7

Is the mirror or lens dirty?

YES

Clean them.
Replace the Scanner Unit.

8

Is the Exposure Lamp dirty?

YES

Clean it.
Replace the Scanner.

9

Are there any bent connector pins on the
cables connecting the control boards,
are any connectors incorrectly plugged
in, or are any cables broken?

YES

Correctly plug in the connectors.
Replace the connection cables.