5) 080: fuser warm up error, T-15 – Konica Minolta PagePro 1390 MF User Manual

Page 125

Advertising
background image

T-15

(5)

080: Fuser warm up error

<Detection Timing>

<Troubleshooting Procedure>

Description

• The voltage of the Thermistor remains low for a predetermined period of time when a

warm-up cycle is started.

• The temperature detected by the Thermistor remains lower than a reference value for a

9 second period of time for the period of time that begins 5 seconds after the start of the
warm-up cycle (where the temperature detected by the Thermistor is 80 °C or less).

• The temperature detected by the Thermistor does not increase for a 3 second or longer

period of time beginning after the lapse of a predetermined period of time after the Fus-
ing Roller Heater Lamp has been turned ON and ending when the lamp is turned OFF.

• The Fusing Roller Heater Lamp remains ON for a 30 second or longer period of time

(except during the period through which the Main Motor remains energized).

Relevant Electrical Parts

Fusing Unit
Thermistor (TH1)

Mechanical Control Board (PWB-A)
Thermostat (TS1)
Power Unit (PU1)

Step

Action

Ref. Page

WIRING DIAGRAM

Control Signal

Location

(Electrical Parts)

1

Replace the Thermistor (TH1).

☞ D-28

2

Replace the Fusing Unit.

☞ E-8

3

Replace PWB-A.

☞ D-11

4

Replace the Power Unit (PU1).

☞ D-14

Advertising