T-42 – Konica Minolta PagePro 1390 MF User Manual

Page 152

Advertising
background image

T-42

xxxx62

DCN

received

• Received Disconnect

command (DCN) from
other side at Phase D.

• Failure in

machine of TX
side

• Check the status

of the machine
of TX side

xxxx63

Too many

CRP

• Received Command

Repeat (CRP) from other
side more than 3 times
after sending (PPS-) Q
Command.

• Line failure

• Retry TX

xxxx64

Too many

PPR

• Received Failure to Train

(FTT) from other side
even with the minimum
speed of 2400 bps.

• Line failure

• Retry TX

xxxx65

RNR time

Out

• Other side was not in RX

mode within 60 seconds
in Flow Control.

• Failure in

remote machine

• Check the status

of the remote
machine

xxxx66

RTN/PIN

Received

• Received Negative

response from other side
for Q Command.

• Line failure

• Retry TX

Comm. Error (at Phase-E)

xxxx70

Time Out

• Did not receive DCN

within 6 seconds at Phase
E.

• Failure in

remote machine

• Line failure

• Check the status

of the remote
machine

• Retry TX