3) 020: h.v. abnormal, 4) 040: laser error, T-14 – Konica Minolta PagePro 1390 MF User Manual

Page 124

Advertising
background image

T-14

(3)

020: H.V. abnormal

<Detection Timing>

<Troubleshooting Procedure>

(4)

040: Laser error

<Detection Timing>

<Troubleshooting Procedure>

Description

• The Drum Charge Monitor Voltage (HVC_MON) signal falls outside a predetermined

range at any time after the lapse of a predetermined period of time after the Power
Switch has been turned ON.

• The Image Transfer Voltage Monitor signal (T_MON_V) and Image Transfer Current

Monitor signal (T_MON_I) fall outside a corresponding predetermined range.

Relevant Electrical Parts

Fusing Unit

Mechanical Control Board (PWB-A)
High Voltage Unit (HV1)

Step

Action

Ref. Page

WIRING DIAGRAM

Control Signal

Location

(Electrical Parts)

1

Replace the Fusing Unit.

E-8

2

Replace HV1.

☞ D-15

3

Replace PWB-A.

☞ D-11

Description

• The laser output exceeds the upper-limit value.
• The laser output remains lower than the lower-limit value.

Relevant Electrical Parts

PH Unit

Mechanical Control Board (PWB-A)

Step

Action

Ref. Page

WIRING DIAGRAM

Control Signal

Location

(Electrical Parts)

1

Check the cables for connection
and correct as necessary.

2

Replace the PH Unit.

☞ D-19

3

Replace PWB-A.

☞ D-11