T-41 – Konica Minolta PagePro 1390 MF User Manual

Page 151

Advertising
background image

T-41

xxxx41

Too many

FTT

• Received Failure to Train

(FTT) from other side
even with the minimum
speed of 2400 bps.

• Failure in

remote machine

• Line failure

• Check the status

of the remote
machine

• Retry TX

xxxx42

Too many

CRP

• Received Command

Repeat (CRP) from other
side more than 3 times
after sending DCS (TCF).

• Failure in

remote machine

• Line failure

• Check the status

of the remote
machine

• Retry TX

xxxx43 T2 Time Out

• Did not receive DCS from

other side within 6 sec-
onds after sending DIS.

• Failure in

remote machine

• Line failure

• Check the status

of the remote
machine

• Retry TX

xxxx44

DCN

received

• Received Disconnect

command (DCN) from
other side at Phase B.

• Failure in

remote machine

• Check the status

of the remote
machine

xxxx45

DTC

Received

• Received Digital Transmit

Command (DTC) from
other side.

• Failure in

remote machine

• Check the status

of the remote
machine

xxxx46

Remote not

capable

for Polling

• Other side was not in Poll-

ing TX when Polling RX.

• Error in opera-

tion on remote
side

• The fax number

is wrong

• Check the Poll-

ing TX setting
of the remote
machine

• Check the fax

number

Comm. Error (at Phase-C)

xxxx50 T2 Time Out

• Did not receive PIX/ECM

from other side within 6
seconds after sending
CFR.

• Failure in

remote machine

• Line failure

• Check the status

of the remote
machine

• Request retry

TX

xxxx51

Image Data

not ready

• Scanner/Encode delayed

in Manual transmission.

• ADF Jam

• Clear the ADF

Jam and retry
TX

xxxx52

Phase-C

Time Out

• Cannot be ready for

Image data within 10 sec-
onds after starting Image
transmission.

• System failure

• Replace the

Controller/
Image Control
Board (PWB-I)

Comm. Error (at Phase-D)

xxxx60

Retry Out

• Did not receive any

response from other side
after three retries of
(PPS-) Q command.

• Line failure

• Retry TX

xxxx61 T2 Time Out

• Did not receive (PPS-) Q

Command from other side
within 6 seconds after
sending PIX/ECM signal
at receiving.

• Failure in

remote machine

• Line failure

• Check the status

of the remote
machine

• Retry TX

Code

Status

Description

Cause

Action

Advertising