BFI/BF1051 / BGEN/es 2956

A delight in freshness

The following ventilation cross-section
and distances
must be observed:

- There must be a ventilation space of

at least 31 square inches
(200 cm

2

) per appliance in the

cabinet plinth and under the cabinet
top panel.

- The depth of the ventilation duct at

the rear of the cabinet must be at
least 1-1/2" (38 mm).

Alternatively:
1. For built-in appliances without

ventilation grilles and only with an
installation frame, ventilation must take
place through the ventilation duct at the
rear of the cabinet.

Built-in appliances with an installation
frame
:

Figure 19:
- Screw the complete installation

frame (2) to the appliance.

2. Built-in appliances with a wooden

ventilation grille:
Figure 20:
Cut out the wooden trim for
use as a ventilation grille using the
enclosed template.
- The required ventilation cross-

section must be at least 31 square
inches (200 cm

2

) when a single

appliance is installed, which
corresponds to template “small” (If
you install two appliances side-
byside, the cross-section must be at
least 62 square inches, 400 cm

2

,

which corresponds to template
“double-size;” for more information
see “Side-by-Side Installation”).

Remove the attachment bracket (2)
from the installation frame and screw it
to the appliance (1) from underneath.
Place the wooden ventilation grille (5)
on the appliance, align it in the center
and secure it from the rear using the
attachment bracket (2).

Figure 19

Figure 20

2

1

5

1/2"

(13 mm)

24"

(609,6 mm)

3-11/16"

(93,7 mm)

LBR038

LBR037

1

At least 31 square inches (200cm

2

)

1

2

1 1/2”

(38mm)

2

0 3

/4

(5

27

m

m

)

I

NSTALLATION