BFI/BF1051 / BGEN/es 2956

3. Open the shut-off valve for the water supply

and check the entire water system for leaks.
Before the appliance is used for the first time a
licensed plumber should bleed air from the
system.

4. Insert the electrical plug for the combined

refrigerator/freezer into the electrical outlet
(Figure 23).

5. Move the combined refrigerator-freezer into

final position in the room.

Figure 23

A delight in freshness

I

CE

M

AKER

Connection to the Water Supply

-

Figures 23, 24

1. Install the shut-off valve, water filter and

automatic shut-off device as required.

Note

The solenoid valve is located at the rear of your
unit.

2. The 1/4" copper tubing between the shut-off

valve and solenoid valve has a 3/4" male
connector

(Figure 24). Make sure there is

approximately 27" (70 cm) of excess tubing
behind the unit for easy connection.

Note

A 3/4" to a 1/4" adapter and cable clip are
supplied with the icemaker.

Remove the cover cap (4) from the solenoid
valve (1). Install the connection bracket (2) with
sealing ring (6) on the solenoid valve (1). Attach
the copper tube to the connection bracket (2).
Secure the copper tube (3) to the appliance
using the cable clip (5).