Nstallation, Uidelines – Liebherr BF1051 User Manual

Page 5

Advertising
background image

I

NSTALLATION

G

UIDELINES

3

BFI/BF1051 / BGEN/es 2956

Area Requirements

Verify the following:

• Floors can support refrigerator’s weight plus

approximately 1200 pounds (544 kg) of food
weight.

• Finish kitchen floor height is level. Refrigerator

must be shimmed to the floor level if the floor
heights are not equal to make sure air vents are
not obstructed.

• Remove anything attached to rear or side walls

that can obstruct refrigerator opening.

• Cutout dimensions are accurate.

• Electrical outlet is in correct location.

Do not install this unit next to another refrigerator or
freezer. This is important to prevent condensation
or consequential damage from another unit.

Electrical Requirement

If codes require a separate grounding circuit to be
used, have a qualified electrician install the circuit.

Do not ground to a gas pipe. Check with a
qualified electrician if you are not sure the
appliance is properly grounded. Do not
have a fuse in the neutral or grounding
circuit.

ELECTRICAL SHOCK HAZARD

• Electrically ground refrigerator.
• Do not use an extension cord.
• Failure to follow these instructions

could result in fire or electrical shock.

!

WARNING

!

WARNING

ELECTROCUTION HAZARD

Electrical Grounding Required. This
appliance is equipped with a three-prong
(grounding) polarized plug for your
protection against possible shock hazards.
DO NOT remove the round grounding

prong from the plug.

DO NOT use a two-prong grounding

adapter.

DO NOT use an extension cord to

connect power to the unit.

Customer’s Responsibility

A 115 Volt, 60 Hz, 15 Amp (20 Amp for side-by-side
installation) fused electrical supply is required. We
recommend using a dedicated circuit for this
appliance to prevent electrical overload. Follow the
National Electrical Code and local codes and
ordinances when installing the receptacle.

Blocking For Safety

The anti-tip brackets must be installed to prevent
the unit from tipping after it is installed. Refer to
Blocking For Safety.

Unit Venting

DO NOT restrict the air flow. Air flow must be
provided for the unit to operate. The factory air
vents provide 31 square inches (200 cm

2

) of air

flow per unit. If you are replacing the factory air
vents with an overlay, the air flow must be the same
or greater than the factory air vents.

!

WARNING

A delight in freshness

BGEN_7082248_0929_Install_3Lang.qxd 10/21/2004 7:56 AM Page 3